Star Hub Alarm Reporting - Nortel DMS-100 Series Maintenance Manual

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-8 Star Remote System manual maintenance
Table 7-7 Power converter full configuration unit status (Sheet 2 of 2)
Power
Power
convertor in
converter in
slot 3
slot 20
Failed
Failed
Installed
Installed
Failed
Installed
Installed
Failed
Failed
Installed
Installed
Failed
Failed
Installed
Installed
Failed
Installed
Installed
Installed
Installed
ILD-R alarms
The ISDN line drawer for remotes (ILD-R) does not generate any alarms. As
a result of ILD-R failure or problems, the ILD-R either goes into ISTb or SysB
states. This, in turn, causes the STAR level to generate an alarm. The
QUERYPM FLT command at the ILD MAP level indicates what problems are
causing the alarm.

Star Hub alarm reporting

Each UMP card supports twelve scan (SC) points and eight SD points that are
user-defined. In addition, three SD points and four SC points are hardcoded
for activating the critical, major, and minor lamps on the FSP dc front panel,
detecting major and critical failures. Minor alarms do not have scan points for
software to detect since hardware never activates a minor alarm.
297-8353-550 Standard 05.01 March 2001
Power
Power
convertor in
converter in
slot 5
slot 18
Installed
Installed
Failed
Failed
Installed
Failed
Failed
Installed
Failed
Installed
Installed
Failed
Installed
Installed
Installed
Installed
Failed
Installed
Installed
Failed
RTS activity
RTS activity
for unit 0
for unit 1
RTS failed
RTS failed
RTS passed,
RTS passed,
ISTb
ISTb
RTS passed,
RTS passed,
ISTb
ISTb
RTS passed,
RTS passed,
ISTb
ISTb
RTS passed,
RTS passed,
ISTb
InSv
RTS passed,
RTS passed,
InSv
ISTb
RTS passed,
RTS passed,
ISTb
InSv
RTS passed,
RTS passed,
InSv
ISTb
RTS passed,
RTS passed,
ISTb
InSv
RTS passed,
RTS passed,
InSv
ISTb

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents