Nortel DMS-100 Series Maintenance Manual page 277

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

33
Insert the +15V fuse, then the -48V fuse.
If the fuse
blows again
does not blow
34
Get a replacement fuse with the same voltage and amperage as the blown
fuse.
35
Remove the blown fuse.
36
Insert the replacement fuse.
If the fuse
blows again
does not blow
37
Reseat all the other line cards in the drawer.
38
Push the drawer back in and go to step 63.
Star Remote System alarm clearing procedures
SRHE frame major
DANGER
Risk of fire
For continued protection against risk of fire, replace the
blown fuse with a fuse of the same type, rating (color code),
and manufacturer.
DANGER
Risk of fire
For continued protection against risk of fire, replace the
blown fuse with a fuse of the same type, rating (color code),
and manufacturer.
DMS-100 Family NA100 Star Remote System XPM15 and up
Do
step 68
step 37
Do
step 68
step 37
11-11
Ext FSP
(continued)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents