4-30 Star Remote System automatic maintenance
field for LCMCOV_REX_TEST, in table REXSCHED, allows a maximum of
one.
Figure 4-4 SREX scheduling
Star
Module
Note 1: REX tests can be running on Star Hub 0 and Star Hub 1 concurrently with REX tests
running on RCC 0 and LGC 0.
Note 2: REX tests could not be running on LCM 2 through LCM 7 if a REX test was running on
LGC 0.
Separating the LCM_REX_TEST and the LCMCOV_REX_TEST allows
faster completion of site REX_TEST coverage. LCM_REX_TESTs, without
constraints of the converter voltage and ring tests, can be run at the same time
and scheduled separately for best execution periods.
Note: The LCMCOV_REX_TEST is performed only on LCMs,
extended-memory line concentrating modules (XLCM), outside plant
modules (OPM), and Remote Line Concentrating Modules (RLCM).
The following tests are also supported for LCM peripherals and its variants:
297-8353-550 Standard 05.01 March 2001
LTC 0
Star Hub
Star Hub
Star
Module
ESA REX test
LCM and ESA-independent REX test
MAP command for manual REX test
Network
LCM 2
RCC 0
RLCM 0
OPM 0
LGC 0
7