Nortel DMS-100 Series Maintenance Manual page 300

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

11-34 Star Remote System alarm clearing procedures
PM STAR
major
(continued)
At the STAR site
6
7
8
9
At the MAP terminal
10
11
297-8353-550 Standard 05.01 March 2001
Inspect the ringing generator to see if the light-emitting diode (LED) is lit.
If the LED light is
lit
not lit
Power up the ringing generator by setting the circuit breakers on the FSP to
the ON position. (The LED should turn OFF.) These circuit breakers are
identified as follows:
circuit breaker marked Ring0, Slot1 controls the ringing generator in unit
0, slot 1
circuit breaker marked Ring1, Slot22 controls the ringing generator in unit
1, slot 22
Determine if the circuit breaker restores power to the ringing generator.
If power
restores and neither unit is SysB step 29
restores and one unit is SysB
does not restore
To perform an in-service test on the STAR to clear the RG fault, type
>TST PM
and press the Enter key.
If the TST
passes
fails and produces card list
To identify C-side links to the host LTC, type
>TRNSL C
and press the Enter key.
Example of a MAP response:
Link 0: LTC 0
Link 1: LTC 0
To post the host LTC, type
>POST LTC pm_no
Do
step 7
step 17
Do
step 17
step 17
Do
step 29
step 28
2; Cap MS; Status: OK
6; Cap MS; Status: SysB
;MsgCond: OPN
;MsgCond: CLS