Nortel DMS-100 Series Maintenance Manual page 29

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

identifies the switches and the correct settings based on the length of this part
of the DS-1 link.
Table 2-3
Distance to cross connect
Feet
Meters
0-133
0-41
133-266
41-81
266-399
81-122
399-533
122-163
533-655
163-200
Note: S indicates switch number(s). On S1 dip switch (6 position): S1-S3 belong
to even port and S4-S6 belong to odd port.
P-side communication cards
The P-side communication cards connect the SRHE to Star Modules with
DS-1 links. Up to 32 DS-1 links can connect to up to 16 Star Modules. The
NTTR87AA and NTMX81AA cards described earlier support these
connections on the P-side. One or two DS-1 links connect each Star Module
to the Star Hub. Like the C-side links, the links to the Star Hub also use
HDLC/LAPD protocol. The paragraph "Star Module to Star Hub DS-1 port
mapping" in this chapter describes the DS-1 link configuration.
Processor card
NTTR77AA (remote controller pack) The remote controller pack (RCP) is the
time slot assignment controller that is in slots 07 and 17. The NTTR77AA
provides
up to 32 message links
8 Mbytes of flash memory
8 Mbytes of dynamic random access memory (DRAM)
processing
clock synchronization
switching matrix that switches any of the 40 input port channels to any
time slot of the 40 output channels
connection to local line drawers
S3/6
On
Off
Off
Off
Off
DMS-100 Family NA100 Star Remote System XPM15 and up
Star Remote System hardware 2-9
S2/5
S1/4
Off
Off
On
On
On
Off
Off
On
Off
Off