Nortel DMS-100 Series Maintenance Manual page 320

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

11-54 Star Remote System alarm clearing procedures
PM STAR
minor
(continued)
41
42
43
44
297-8353-550 Standard 05.01 March 2001
To manually busy the link, type
>BSY rldcarrier_no
and press the Enter key.
where
rldcarrier_no
is the number of the DS-1 link (0 or 1) as viewed by the RLD
To return the ManB link to service, type
>RTS rldcarrier_no
and press the Enter key.
where
rldcarrier_no
is the number of the DS-1 link (0 or 1) as viewed by the RLD
If RTS LINK
passes
fails
To display information on the Bd channel, type
>QUERYCH
and press the Enter key.
Example of a MAP response:
SysB
PM
4
STAR
0
STAR REM1 00 0
ISTb
Unit 0:
ISTb
Unit 1:
ManB
Drwr:
11 11 11 11 11 22 22 22 22 22 33 33 33
01 23 45 67 89 01 23 45 67 89 01 23 45 67 89 01 23 45
MM .M –– –– –– –– –– –o ss –– –– –– –– –– –– –– –– ––
REM9 RLD DRWR
8 ISTb
BANK_0:
Active
BANK_1: Stby
QUERYCH
RLD BD
To return the Bd channel to service, type
>RTS BD
and press the Enter key.
If the RTS
passes
Do
step 61
step 59
ManB
OffL
CBsy
0
10
0
0
Links_OOS: CSide 0 PSide 0 UMP OOS:0
/RG: 0
/RG: 0
LogDrwr:
Links_OOS: 1
RLD BDch:
Do
step 61
ISTb
InSv
3
3
0
1
RG
Pref 0 InSv
Stby 1 InSv
16
17
3
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents