Nortel DMS-100 Series Maintenance Manual page 381

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

drawer 1 and any fuse in position 2 is associated with line drawer 2, and
so forth.
13
Remove the +15V fuse for the line drawer containing the faulty bus interface
card. The +15 V fuse for the line drawer is numbered the same as the -48 V
fuse removed in step 12.
14
Remove the +5V fuse for the line drawer containing the faulty bus interface
card. Determine the correct fuse number by using the table in step 12.
If entry into this procedure is
because of
replacement of BIC
loss of power in STAR's
controller
15
Star Remote System card replacement procedures
WARNING
Static electricity damage
Before removing any cards, put on a wrist strap and connect
it to the wrist strap grounding point on the left side of the
frame supervisory panel (FSP) of the STAR. This protects the
equipment against damage caused by static electricity.
WARNING
Card damage—transport
Take the following precautions to protect circuit cards from
electrical and mechanical damage during transport:
When handling a circuit card not in an electrostatic discharge
(ESD) protective container, stand on a conductive floor mat.
Wear a wrist strap connected, through a 1-megohm resistor,
to a suitably grounded object, such as a metal workbench or a
DMS switch cabinet (Nortel Networks Corporate Standard
5028). Store and transport circuit cards in an ESD protective
container.
DMS-100 Family NA100 Star Remote System XPM15 and up
in a STAR
Do
step 15
step 19
12-33
NT6X54
(continued)

Hide quick links:

Advertisement

Table of Contents
loading