11-8 Star Remote System alarm clearing procedures
Ext FSP
SRHE frame major
18
19
20
297-8353-550 Standard 05.01 March 2001
(continued)
CAUTION
Loss of service
Perform this procedure during periods of low traffic.
Pull out the line drawer you have just identified.
Note: When dealing with a blown ringing fuse (56 to 63), begin with the
first LSG in the group.
DANGER
Personal injury
Exercise care when handling the line card. The line feed
resistor may be hot.
Unseat all the line cards in the drawer.
Note: Just unseat the line cards, do not remove them from the drawer.
If you are dealing with
any one of +5 V fuses
any one of +15 V or -48 V fuses
any one of ringing fuses
DANGER
Risk of fire
For continued protection against risk of fire, replace the
blown fuse with a fuse of the same type, rating (color code),
and manufacturer.
Do
step 21
step 20
step 21

Hide quick links: