11-26 Star Remote System alarm clearing procedures
PM STAR
critical
(continued)
26
27
28
29
30
297-8353-550 Standard 05.01 March 2001
If test
failed, and a card list is
generated
failed, and no card list was
generated
The card list identifies the cards most likely to be faulty. Replace the cards
one at a time in the order listed as directed by this procedure.
If last card on list has
not been replaced
been replaced
Attempt to return the STAR to service by typing
>RTS PM
and pressing the Enter key.
If MAP prompt indicates
RTS is successful
CBsy
load failure
all other
Attempt to reload the STAR by typing
>LOADPM PM CC
and pressing the Enter key.
If load is
successful
not successful
not successful in one unit
Contact the carrier maintenance support group for maintenance on the
open/unstable links. When carriers are restored, go to step 22.
Contact your maintenance support group for further instructions in clearing
this fault.