Nortel DMS-100 Series Maintenance Manual page 416

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

12-68 Star Remote System card replacement procedures
NTEX17
in a STAR
(end)
At the xEMS workstation
19
20
21
22
23
24
297-8353-550 Standard 05.01 March 2001
At the submap of the LCM line drawer with the NTEX17 card that you
replaced.
Place the cursor on the the XLC card you want to return the card to service
and use the mouse to select
Maintenance : XLC -> IDL
and press the Enter key.
Send any cards with faults for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
indications that prompted replacement of the card
Go to step 24.
Get additional assistance in replacing this card by contacting personnel
responsible for a higher level of support.
The procedure is complete.