Nortel DMS-100 Series Maintenance Manual page 314

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

11-48 Star Remote System alarm clearing procedures
PM STAR
minor
(continued)
18
19
20
297-8353-550 Standard 05.01 March 2001
To busy both line subgroups associated with the drawer with faults, type
>BSY DRWR lsg
and press the Enter key
where
lsg
is the number of the line subgroups associated with the drawer with
faults
Example of a MAP response:
STAR
REM1 00 0
Repeat this step for the other line subgroup associated with the drawer with
faults.
To test both line subgroups associated with the drawer with faults, type
>TST DRWR lsg
and press the Enter key.
where
lsg
is the number of one of the line subgroups associated with the drawer
with faults
Note: Repeat this step for the other line subgroup associated with the
drawer with faults.
If test
passed
failed, and a card list is produced step 52
failed, but no card list is pro-
duced
To return to service both line subgroups, type
>RTS DRWR lsg
and press the Enter key.
where
lsg
is the number of one of the line subgroups associated with thedrawer
with faults
Example of a MAP response:
OSvce Tests Initiated
STAR
REM1 00 0
STAR
REM1 00 0
Drwr 16 Bsy Passed
Do
step 20
step 59
Drwr 16 Tst Passed
Drwr 16 Rts Passed

Hide quick links: