Nortel DMS-100 Series Maintenance Manual page 287

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

ltc_no
is the number of the LTC
7
Display the peripheral side (P-side) links by typing
>TRNSL P
and pressing the Enter key.
Example of a MAP response:
Link 2: STAR REM1 00 0
Link 6: STAR REM1 00 0
Record information for the links that have a status other than OK.
8
Busy the faulty link by typing
>BSY LINK
and pressing the Enter key.
where
link_no
is the number of a faulty P-side link identified in step 7
9
Test the busied link by typing
>TST
LINK link_no
and pressing the Enter key.
where
link_no
is the number of a faulty P-side link busied in step 8
If test
passed
failed
10
Return to service (RTS) the busied link by typing
>RTS
LINK
and pressing the Enter key.
where
link_no
is the number of a faulty P-side link tested in step 9
If RTS
passed and no other links are
system busy (SysB)
passed but other links are SysB
Star Remote System alarm clearing procedures
2; Cap MS; Status: SysB ;MsgCond: CLS
1; Cap MS; Status: SysB ;MsgCond: CLS
link_no
link_no
DMS-100 Family NA100 Star Remote System XPM15 and up
critical
Do
step 10
step 30
Do
step 11
step 8
11-21
PM STAR
(continued)