Nortel DMS-100 Series Maintenance Manual page 301

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

and press the Enter key.
where
pm_no
is the number of the host LTC
12
To identify the P-side links with faults, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
Link 2: STAR REM1 00 0
Link 6: STAR REM1 00 0
Record information for the links that have a status other than OK.
13
To busy the link with faults, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number the P-side link identified in step 12
14
To test the busied link, type
>TST LINK link_no
and press the Enter key.
where
link_no
is the number of the P-side link busied in step 13
If test
passes
fails
15
To return the busied link to service, type
>RTS LINK link_no
and press the Enter key.
where
Star Remote System alarm clearing procedures
2;Cap MS;Status: OK
1;Cap MS;Status: SysB,;MsgCond: CLS
DMS-100 Family NA100 Star Remote System XPM15 and up
major
;MsgCond: OPN
Do
step 15
step 27