Nortel DMS-100 Series Maintenance Manual page 445

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP terminal
23
To test the busied links from step 10, type
>TST LINK link_no
and press the Enter key
where
link_no
is the number of the link that was manually busied in step 10.
Note 1: This step must be performed for each link that is manually busied.
Note 2: To test the other links connected to the STAR, execute this step
for each link until all links are tested.
If TST
passes
fails
24
To return to service the P-side links, type
>RTS LINK link_no
and press the Enter key.
where
link_no
is the number of the link that was tested in step 23.
Note: To RTS the other links connected to the STAR, perform this step for
each link until all links are returned to service.
If RTS
passes
fails
25
To post the STAR where the NTMX81 card is located, type
>POST STAR site frame unit
and press the Enter key.
where
site
is the name of the site where the STAR is located
frame
is the frame number of the STAR with the card with faults (0 to 511)
unit
is 0 for the STAR
Star Remote System card replacement procedures
DMS-100 Family NA100 Star Remote System XPM15 and up
in a STAR
Do
step 24
step 34
Do
step 25
step 34
12-97
NTMX81
(continued)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents