12-152 Star Remote System card replacement procedures
NTTR73
in a STAR
(continued)
Replacing an NTTR73 card in a STAR
At your current location
1
2
3
At the MAP terminal
4
TSTEQUIP
UMP
PM
STAR
5
6
At the STAR control shelf
7
At the MAP terminal
8
9
297-8353-550 Standard 05.01 March 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Get a replacement card. Make sure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
If you were directed to this procedure from another maintenance procedure,
go to step 7. Otherwise, continue with step 4.
To access the test equipment (TSTEQUIP) level and post all UMPs, type
>MAPCI;MTC;MTCNA;TSTEQUIP;POST UMP ALL
and press the Enter key.
Example of a MAP response:
SysB
ManB
0
0
0
0
MTE
STATE
REM1 0 0
0
Use the NEXT command to post the next UMP in the posted set until you
access the UMP that is in the SysB state.
To busy the SysB UMP card posted in step 5, type
>BSY
and press the Enter key.
Replace the NTTR73 card using the common replacing a card procedure in
this document. When the card is replaced, return to this point.
To load the UMP card, type
>LOADTE
and press the Enter key.
If you were directed to this procedure from another maintenance procedure,
return now to the alarm clearing procedure that directed you here. Otherwise,
continue with step 10.
OffL
CBsy
2
0
2
0
CBSY
ISTb
InSv
1
12
1
9