12-124 Star Remote System card replacement procedures
NTTR66
in an RLD
(end)
8
9
10
At the MAP terminal
11
12
13
14
15
297-8353-550 Standard 05.01 March 2001
WARNING
Static electricity damage
Wear a wrist strap connected to the wrist strap grounding
point on the frame supervisory panel (FSP) while handling
cards. This precaution protects the cards against damage
caused by static electricity.
Carefully remove the EMI card. Place the card you removed in an
electrostatic discharge (ESD) protective container.
Install the replacement card.
Close the TSS cover, if necessary and close the Star Module.
To return the line cards to service, type
>RTS lsg ckt_range
and press the Enter key.
where
lsg
is the number of the line subgroup with the faulty card (0-1)
ckt_range
is the range of circuits associated with the faulty card, such as 0-15 or
16-31
If RTS
passed
failed
Send any cards with faults for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
problems that prompted replacement of the card
Go to step 15.
Get additional support in replacing this card by contacting the operating
company personnel responsible for higher level of support.