If the STAR
does not have dial tone
15
Determine if the STAR has the ESA timer set for manual recovery from ESA.
To access table OFCENG, type
>TABLE OFCENG
and press the Enter key.
16
To check the STAR exit time, type
>POS RLCM_XPMESAEXIT
and press the Enter key.
Example of a MAP response:
PARMNAME
If PARMVAL is
set to zero
greater than zero
17
Before manually restoring the STAR from ESA, check to see if links to the
STAR are stable. To find the link numbers for this STAR, type
>TRNSL C
and press the Enter key.
Example of a MAP response:
Host XPM P-side link number
Link 0: LTC 1
Link 1: LTC 1
Link 2: LTC 1
Link 3: LTC 1
18
To access the CARRIER level of the MAP, type
>TRKS;CARRIER
and press the Enter key.
19
To post the host LTC links and check link conditions for slips and framing
errors, type
>POST pm_type pm_no link_no
and press the Enter key.
Star Remote System recovery procedures
Star Hub recovery procedure
RLCM_XPMESAEXIT
0 ; Cap MS ; Status : OK ; MsgCon : OPN
2 ; Cap MS ; Status : OK ; MsgCon : OPN
3 ; Cap
S ; Status : OK
4 : Cap
S ; Status : OK
DMS-100 Family NA100 Star Remote System XPM15 and up
Do
step 21
PARMVAL
3
Do
step 17
Allow the system to recover the
STAR. Go to step 29