Nortel DMS-100 Series Maintenance Manual page 170

Star remote system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-10 Star Remote System user interface
Figure 6-4 Example of a QUERYPM FLT command at the STAR level
CM
MS
.
.
STAR
0
Quit
2
Post_
3
ListSet
4
SwRg_
5
Trnsl_
6
Tst_
7
Bsy_
8
RTS_
9
Offl
10 LoadPM_
11 Disp_
12 Next
13
14 QueryPM
15 PES
16 ILD
17 RLD
18 RLDCarr
userid
TIME
hh : mm>
When the command string QUERYPM FLT is entered, one of the following
unit-related or node-related ISTb reasons can also be displayed.
Line drawer state display
At the STAR level of the MAP display, the status of the drawers is displayed
below the status of the Star Hub units. The drawers are numbered from 1
through 18. For the Star Hub, the MAP display shows the line subgroups
297-8353-550 Standard 05.01 March 2001
IOD
Net
PM
CCS
.
.
4 SysB
M
SysB
PM
4
STAR
0
STAR REM1 00 0
ISTb
Unit 0:
ISTb
Unit 1:
ManB
Drwr:
11 11 11 11 11 22 22 22 22 22 33 33 33
01 23 45 67 89 01 23 45 67 89 01 23 45 67 89 01 23 45
.. .. –– –– –– –– –– –– –– –– –– –– –– –– –– –– –– ––
QUERYPM FLT
Node inservice troubles exist:
One or both Units inservice trouble
STAR UNIT 0 ISTB
STAR UNIT 1 MANB
PM overloaded
STAR Node ISTb reasons
— One or both MTC packs out of service
— MTC pack load file mismatch
— Fuse card fault
— ESA option is blocked within both LCM units
— Inter Unit Communication fault
STAR Unit ISTb reasons
— LCM ESA Static Data or EXECs invalid
— LCM ESA translation data invalid
— All other LCM relevant faults that related to LCM self testing
i.e. drawers testing
Lns
Trks
.
.
.
ManB
OffL
0
10
0
0
Links_OOS: CSide 0 PSide 0 UMP OOS:0
/RG: 0
/RG: 0
Ext
Appl
.
.
CBsy
ISTb
3
3
0
1
RG
Pref 0 InSv
Stby 1 InSv
InSv
3
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents