2.5 Subscan Unit
9.
Secure the steel belt and the paper onto the top cover so
that they will not fall off.
10.
Loosen a set screw on the coupling.
11.
Remove 6 fixing screws, and remove the steel belt deceler-
ating unit.
12.
Carry out reassembly in the reverse order to that described
above.
I m p o r t a n t
When securing the steel belt to the bal-
ance weight, check that the steel belt is
not pinched between the bearing and
washer.
Adjustment after installation
Carry out an solid image exposure, and check that there is no
horizontal stripes or artifacts caused by malfunction of the sub-
scan unit.
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01