Scb2 Error Codes - Konica Minolta REGIUS 190 Service Manual

Hide thumbs Also See for REGIUS 190:
Table of Contents

Advertisement

4.4.7

SCB2 Error Codes

Code
Medium Classifi-
cation
Memory error
10000
Hardware error
11000
Internal communi-
12000
cation error
Internal error
12001
Internal error
12002
Internal error
12003
Internal error
12010
Internal error
12011
Internal error
12200
12201
Internal error
Internal error
12202
Internal error
12203
Internal error
12204
Detailed Clas-
sification
Mechanical
High voltage ON
control com-
Timeout
munication
Mechanical
Laser ON Timeout
control com-
munication
Mechanical
Mech Ready Time-
control com-
out
munication
Mechanical
Standby Timeout
control com-
munication
Mechanical
Resent counts
control com-
Overflow
munication
Mechanical
CRC Erorr counts
control com-
Over-flow
munication
Network com-
Net Initialize Time-
munication
out
Network com-
Net Ready Timeout Open and close the door and then
munication
Network com-
Put Shading Time-
munication
out
Network com-
Status Check Time-
munication
out
Network com-
Barcode Seek Tim-
munication
eout
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01
Countermeasures, etc.
SCB2 replacement or CF card
replacement
SCB2 replacement
Confirm that there was no continuous
insertion.
Open and close the door and then
restore. If restoration is not possi-
ble, restart.
Open and close the door and then
restore. If restoration is not possible,
restart. Following restart, confirm the
following.
LD peripherals (LD power supply
and optical unit)
Check the wiring on the board.
Open and close the door and then
restore. If restoration is not possible,
restart.
Open and close the door and then
restore. If restoration is not possible,
restart.
Open and close the door and then
restore. If restoration is not possible,
restart.
Open and close the door and then
restore. If restoration is not possible,
restart.
Open and close the door and then
restore. If restoration is not possible,
restart. If the problem then reoccurs,
confirm whether the JM is operating.
Also confirm that the device is con-
nected to the net.
restore. If restoration is not possible,
restart.
Open and close the door and then
restore. If restoration is not possible,
restart.
Open and close the door and then
restore. If restoration is not possible,
restart.
Open and close the door and then
restore. If restoration is not possible,
restart.
4.4 Error Code