2.4 Transport Unit
2
Part Name
1 Justification HP
sensor (S9)
2 Justification Sen-
sor-L (S3)
3 Justification Sen-
sor-R (S4)
4 Justification Motor
(PM2)
1
Function
Access to the Part
Detects the HP of the
1) Open the front cover, and tilt the Transport Unit using
justification mecha-
nism.
2) Remove a fixing screw, and remove the sensor.
3) Unplug a connector.
Detects the left end
1) Open the front cover, and tilt the Transport Unit using
when justifying.
2) Bring the justification mechanism to the center by hand.
3) Remove a fixing screw, and remove the justification
4) Remove the sensor from the justification sensor mount
5) Unplug a connector.
Detects the right end
1) Open the front cover, and tilt the Transport Unit using
when justifying.
2) Bring the justification mechanism to the center by hand.
3) Remove a fixing screw, and remove the justification
4) Remove the sensor from the justification sensor mount
5) Unplug a connector.
Drives the mecha-
Refer to
nism via timing belt.
(PM2),
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01
handle.
• JP32
handle.
sensor mount plate.
plate.
• JP22
handle.
sensor mount plate.
plate.
• JP23
"2.4.3 Replacement of the Justification Motor
p.55".
4
3
51