A.1 SCB2 Dummy Program Screens
•
[DC Motors] Tab
Key
Insertion slot shut-
[Initialize]
ter
[Open]
[Close]
Lock-release motor [Lock]
Insertion roller
[Forward High]
[Forward Low]
[Reverse]
[Stop]
Ejection roller
[Forward]
[Stop]
178
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01
Description
Initiates initializing of the insertion shutter. (open, close, and check
the operation is normal)
Opens the insertion shutter.
Closes the insertion shutter.
Plunge the cassette lock one time.
Initiates normal rotation (to draw the cassette) of the insertion roller
at high speed.
Initiates normal rotation (to draw the cassette) of the insertion roller
at low speed.
Initiates reverse rotation (to eject the cassette) of the insertion roller.
Stops the rotation of the insertion roller.
Initiates normal rotation (to eject the cassette) of the ejection roller.
Stops the rotation of the ejection roller.