6
7
8
9
10
•
If the back panel attaches normally, the absorption sensor
turns on.
•
The subscan motor starts to operate and the absorption
plate moves upward.
•
If one of the peel sensors turns on, it will indicate that the
plate condition is not normal; in such a case, the upward
motion is halted and the mechanism returns to the subscan
home position.
•
Several seconds after the V-SYNC sensor turns on, the laser
also turns on and image reading operations start.
•
When the image reading has been completed, the absorp-
tion plate moves down and simultaneously the erasing
lamps turn on.
•
The cassette is fed to the ejection shutter in the reverse
order to that described above.
•
The Cassette receive Unit moves up to the standby position.
•
The actual stop position will depend on the size of the cas-
sette.
•
The tip of the cassette comes into contact with the ejection
roller.
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01
1.5 Description of Operation
21