2.4 Transport Unit
Part Name
2 Feed HP Sensor (S10)
3
(PM3)
Controlling parts for justification mechanism
I m p o r t a n t
Do not remove the bracket on which the justification HP sensor is mounted.
I m p o r t a n t
Do not touch the antislip rubber which is attached on the part where the cassette frame
comes in contact.
Justification Mechanism
(3 different views)
50
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01
Function
Access to the Part
Detects the HP of
1) Remove the right cover.
the base.
•(Refer to "Removal of the Left & Right Covers, p.29")
2) Remove two fixing screws, and remove the transport
sensor bracket.
3) Remove a fixing screw, and remove the sensor from
the bracket.
4) Unplug a connector.
• JP33
Drives the base.
Refer to
p.60"
"2.4.6 Replacement of Transport Motor (PM3),
Antislip Rubber Caution : Do not touch