2.3 Insertion / Ejection Unit
2.3.7

Replacement of Shutter Motor (M2)

1.
Remove the insertion / ejection unit. ("2.3.2Removal of the
Insertion/Ejection Unit", p.37)
2.
Remove the insertion / ejection unit front cover.
Removal of Insertion / Ejection Front Cover,
3.
Remove an E-ring, and then an idler gear.
At the same time, a parallel pin will also become free. Be
cautious not to loose this pin.
4.
Remove the wire bundle from the wire clamp. Then unplug a
connector.
JJ48
5.
Remove two fixing screws, and remove the shutter motor
(M2).
6.
Carry out reassembly in the reverse order to that described
above.
44
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01
("2.2.4
p.31")
Connector
Fixing Screw
Shutter Motor (M2)
E-Ring
Idler Gear
Parallel
Pin