Adjusting The Peel-Detection Rollers; Peel Detection Mechanism - Konica Minolta REGIUS 190 Service Manual

Hide thumbs Also See for REGIUS 190:
Table of Contents

Advertisement

3.6 Adjusting the Peel-Detection Rollers

3.6 Adjusting the Peel-Detection Rollers
3.6.1

Peel detection mechanism

The REGIUS 190 has been designed such that, when subscanning operation is being carried out, there is a gap
of approximately 1 mm between the optical beam condensing section and the plate surface. However, in situa-
tions such as where abnormal adherence of double-sided adhesive tape leads to peeling of the plate from the
back plate, any attempted subscanning operation could result in interference of the plate with the optical unit. In
order to avoid such interference, a peel detection roller is provided in the position where the elevating plate is just
enters the operational area of optical unit.
Main Components of Peel Detection Mechanism
1
Sensor Actuator
2
Shaft "A"
Back Plate
3
4
5
REGIUS Plate
Shaft "B"
6
Magnetizing Plate
117
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01