Siemens SINAMICS G110M Operating Instructions Manual page 150

Distributed converter for simogear geared motors
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

Protecting the converter settings
7.2 Know-how protection
• Locked functions:
– Downloading converter settings using a PC
– Automatic controller optimization
– Stationary or rotating measurement of the motor data identification
– Deleting the alarm history and the fault history
– Generating acceptance documents for safety functions
• Executable functions:
– Restoring factory settings
– Acknowledging faults
– Displaying faults, alarms, fault history, and alarm history
– Reading out the diagnostic buffer
– Controlling a converter using a PC
– Uploading adjustable parameters that can be changed or read when know-how
– Displaying acceptance documents for safety functions
When know-how protection is active, support can only be provided (from Technical Support)
after prior agreement from the machine manufacturer (OEM).
Know-how protection without copy protection
You can transfer the converter settings to another converter, e.g. using a memory card or an
operator panel.
Know-how protection with basic copy protection
After replacing a converter, to be able to operate the new converter with the settings of the
replaced converter without knowing the password, the memory card must be inserted in the
new converter.
Know-how protection with extended copy protection
It is not possible to insert and use the memory card in another converter without knowing the
password.
Commissioning know-how protection
1. Check as to whether you must extend the exception list.
2. Activate the know-how protection.
148
protection is active.
List of exceptions (Page 151)
Know-how protection (Page 152)
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents