Parameter
Table 8-4
Parameter
r0052[0...15] CO/BO: Status word 1
r0053[0...11] CO/BO: Status word 2
A complete list of the binector inputs is provided in the List Manual.
Further information
You can invert the digital output signal using parameter p0748.
Additional information is provided in the parameter list and in function diagram 2241.
Manuals and technical support (Page 415)
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
Binector outputs of the converter (selection)
Description
.00
1 signal: Ready for switching on
.01
1 signal: Ready for operation
.02
1 signal: Operation enabled
.03
1 signal: Fault active: The converter inverts signal
r0052.03 if it is interconnected to a digital output.
.04
0 signal: OFF2 active
.05
0 signal: OFF3 active
.06
1 signal: Switching on inhibited active
.07
1 signal: Alarm active
.08
0 signal: Deviation, setpoint/actual speed
.09
1 signal: Control request
.10
1 signal: Maximum speed (p1082) reached
.11
0 signal: I, M, P limit reached
.13
0 signal: Alarm, motor overtemperature
.14
1 signal: Motor clockwise rotation
.15
0 signal: Alarm, converter overload
.00
1 signal: DC braking active
.02
1 signal: Speed > minimum speed (p1080)
.06
1 signal: Speed ≥ setpoint speed (r1119)
8.4 Adapt the default setting of the inputs and outputs
Advanced commissioning
Factory setting
-
-
165