Function
6
Commissioning with predefined motor data for SIMOTICS GP/SD synchro‐
nous-reluctance motors:
Second generation: 1FP1 . 04 → 1FP1 . 14
Further frame sizes:
– 1.1 kW ... 3 kW, 1500 1/min, 1800 1/min, 2810 1/min
– 0.75 kW ... 4 kW, 3000 1/min, 3600 1/min
In planning:
– 37 kW ... 45 kW, 1500 1/min, 1800 1/min, 2810 1/min
– 5.5 kW ... 18.5 kW, 3000 1/min, 3600 1/min
– 45 kW, 3000 1/min, 3600 1/min
– The predefined motor data is already included in the firmware
7
Extended setting option for evaluating the STOP cam in the "basic positioner"
function
Two different functions to evaluate STOP cams can be set:
Edge-triggered evaluation (factory setting)
Level-triggered evaluation
For more information, refer to the "Basic Positioner" Function Manual or the
operating instructions for "SINAMICS G120D Converter with CU250D-2 Con‐
trol Units".
"Basic positioner" function manual
support.industry.siemens.com/cs/ww/en/view/109477922)
Operating instructions SINAMICS G120D with CU250D-2
support.industry.siemens.com/cs/ww/en/view/109477365)
Installation with PM240-2 or PM240P-2 Power Modules
1)
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
(https://
(https://
A.1 New and extended functions
SINAMICS
G120
-
-
-
1)
-
-
-
-
-
Appendix
G120D
-
-
-
-
399