• IND, bit 8 ... 15 (subindex): = 1 hex (CDS1 = Index 1)
• IND, bit 0 ... 7 (page index): = 0 hex (offset 0 corresponds to 0 hex)
• PWE1, Bit 0 ... 15: = 2D2 hex (722 = 2D2 hex)
• PWE2, Bit 10 ... 15: = 3F hex (drive object - for SINAMICS G120, always 63 = 3f hex)
• PWE2, Bit 0 ... 9: = 2 hex (Index of Parameter (DI 2 = 2))
Figure 8-18
Telegram, to assign DI 2 with ON/OFF1
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
Advanced commissioning
8.6 Drive control via PROFIBUS or PROFINET
203