Siemens SINAMICS G110M Operating Instructions Manual page 345

Distributed converter for simogear geared motors
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

Selecting the number of drive data sets
The number of drive data sets (1 ... 4) is defined by parameter p0180.
Parameter
p0010 = 0
p0010 = 15
p0180
Copying the drive data sets
Parameter
p0819[0]
p0819[1]
p0819[2] = 1
Parameter
Parameter
p0010
r0051
p0180
p0819[0 ... 2]
p0820[C]
p0821[C]
p0826[M]
Further information
The converter switches the motor data set (MDS) and the power unit data set (PDS) together
with the drive data set (DDS).
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
Description
Drive commissioning parameter filter
CO/BO: Drive data set DDS effective
Number of Drive Data Sets (DDS)
Copy drive data set DDS
BI: Drive data set DDS selection, bit 0
BI: Drive data set DDS selection, bit 1
Motor changeover, motor number
Advanced commissioning
8.30 Switchover between different settings
Description
Drive commissioning: Ready
Drive commissioning: Data sets
Number of Drive Data Sets (DDS)
Description
Source drive data set
Target drive data set
Starts the copy operation
Factory setting
1
-
1
0
0
0
0
343

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents