safety functions, are in a position to perform the acceptance test in the correct and appropriate
manner.
Wizard for the acceptance test
The "Startdrive Advanced" commissioning tool (requires an appropriate license) includes a
wizard for the acceptance test of the safety functions integrated in the drive.
"Startdrive Advanced" guides you through the acceptance test, generates the appropriate traces
to analyze the machine response – and generates an acceptance report as Excel file.
Further information is provided on the Internet:
support.industry.siemens.com/cs/ww/en/view/109752254)
Reduced acceptance test after function expansions
A full acceptance test is necessary only after first commissioning. A reduced acceptance test is
sufficient when safety functions are expanded.
Measure
Functional expansion of the ma‐
chine (additional drive).
Transfer of converter settings to
other identical machines by means
of series commissioning.
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
Startdrive, system requirements and download
8.15 Safe Torque Off (STO) safety function
(https://
Acceptance test
Acceptance test
Documentation
Yes.
Only check the safety
functions of the new
drive.
No.
Only check the control
of all of the safety func‐
tions.
Advanced commissioning
Supplement machine overview
Supplement converter data
Add function table
Log the new checksums
Countersignature
Add machine description
Check checksums
Checking the firmware versions