Motorized Potentiometer As Setpoint Source - Siemens SINAMICS G110M Operating Instructions Manual

Distributed converter for simogear geared motors
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

8.16.5

Motorized potentiometer as setpoint source

Function description
The "Motorized potentiometer" function emulates an electromechanical potentiometer. The
output value of the motorized potentiometer can be set with the "higher" and "lower" control
signals.
Figure 8-41
Figure 8-42
Example
Setting with the motorized potentiometer as setpoint source:
Parameter
p1070 = 1050
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
Motorized potentiometer as setpoint source
Function chart of the motorized potentiometer
Description
Interconnects the main setpoint with the motorized potentiometer output.
Advanced commissioning
8.16 Setpoints
263