If you don't need the switching of 2L+ power supply, then both the switched as well as the non-
switched 24 V may come from the same supply.
X01
X02
Type: 7/8 " - 16UN connector, female
I/O terminal diagram - all varaints
The maximum combined current for all digital inputs is 200 mA and the maximum combined
current for all digital outputs is 500 mA.
X05
X07
X08
X10 / X15
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
4.3 Electrical Installation
HANQ
Glanded
M12 connector, 5 Pole, female
Specification:
2
PNP, SIMATIC-compatible, low
1
5
3
<5 V, high > 10 V maximum,
4
input voltage 30 V.
The Control Module (CM) is fit‐
2
ted inside the terminal housing
1
5
3
and is connected by ribbon ca‐
4
ble to the CPI.
2
1
5
3
4
M12 connector, 8 Pole, female
X10 for USS, Profibus and
1
2
Profinet,
7
8
3
6
X15 for AS-i
4
5
Installation