Connecting
6.16 Connector assignment (terminals, Faston mounting tabs, ribbon cables)
6.16.9

Ribbon cables

Firing pulse cable, torque direction 1, connectors X21A/X21PAR
Ribbon cable, 26-pin
Table 6- 34
Assignment X21A, X21PAR
Function
Free
Free
Free
Electronic ground
Thyristor firing pulse, armature 2
24 V supply, firing
Electronic ground
Thyristor firing pulse, armature 6
24 V supply, firing
Electronic ground
Thyristor firing pulse, armature 4
24 V supply, firing
Electronic ground
Thyristor firing pulse, armature 5
24 V supply, firing
Electronic ground
Thyristor firing pulse, armature 3
24 V supply, firing
Electronic ground
Thyristor firing pulse, armature 1
24 V supply, firing
Electronic ground
Actual current value
Ground reference for actual current value
Electronic ground
Free
Power interface for the Control Module / firing pulse transformer module
Connectors X21A and X21PAR are connected in parallel on the firing pulse transformer module,
except for I_IST (pin 23) and M_I_IST (pin 24)
150
Pin
Signal name
1
2
3
4
M
5
IMP_12
6
P24_Z
7
M
8
IMP_16
9
P24_Z
10
M
11
IMP_14
12
P24_Z
13
M
14
IMP_15
15
P24_Z
16
M
17
IMP_13
18
P24_Z
19
M
20
IMP_11
21
P24_Z
22
M
23
I_IST
24
M_I_IST
25
M
26
Operating Instructions, 12/2018, A5E34888669A
Connection values /
comments
24 V / 2 A pulse
24 V DC / 2 A
24 V / 2 A pulse
24 V DC / 2 A
24 V / 2 A pulse
24 V DC / 2 A
24 V / 2 A pulse
24 V DC / 2 A
24 V / 2 A pulse
24 V DC / 2 A
24 V / 2 A pulse
24 V DC / 2 A
analog ±10 V
analog ±10 V
SINAMICS DCM Control Module

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics dc master