Descriptions of functions
10.3 Communication according to PROFIdrive
Error values in DPV1 parameter responses
Table 10- 31 Error values in DPV1 parameter responses
Error
Meaning
value
0x00
Illegal parameter number.
0x01
Parameter value cannot be changed.
0x02
Lower or upper value limit exceeded.
0x03
Invalid subindex.
0x04
No array.
0x05
Wrong data type.
0x06
Illegal set operation (only reset
allowed).
0x07
Description element cannot be
changed.
0x09
No description data available.
0x10
Read job will not be executed.
0x0B
No operating priority.
0x0F
No text array exists.
0x11
Request cannot be executed due to
operating status.
0x14
Illegal value.
0x15
Response too long.
0x16
Illegal parameter address.
0x17
Illegal format.
0x18
Number of values inconsistent.
0x19
Drive object does not exist.
0x20
Parameter text cannot be changed
0x21
Service not supported.
0x65
Parameter presently deactivated.
414
Remark
Access to a parameter that does not exist.
Modification access to a parameter value that cannot be
changed.
Modification access with value outside value limits.
Access to a subindex that does not exist.
Access with subindex to non-indexed parameter.
Modification access with a value that does not match the
data type of the parameter.
Modification access with a value not equal to 0 in a case
where this is not allowed.
Modification access to a description element that cannot be
changed.
Access to a description that does not exist (the parameter
value exists).
The read request is refused because know-how protection is
active.
Modification access with no operating priority.
Access to a text array that does not exist (the parameter
value exists).
Access is temporarily not possible for unspecified reasons.
Modification access with a value that is within the limits but
is illegal for other permanent reasons (parameter with
defined individual values).
The length of the present response exceeds the maximum
transfer length.
Illegal or unsupported value for attribute, number of
elements, parameter number, subindex or a combination of
these.
Write request: Illegal or unsupported parameter data format.
Write request: A mismatch exists between the number of
values in the parameter data and the number of elements in
the parameter address.
You have tried to access a drive object that does not exist.
Illegal or unknown request ID
You have tried to access a parameter that, although
available, does not currently perform a function
(e.g. n control set and access to a V/f control parameter).
SINAMICS DCM Control Module
Operating Instructions, 12/2018, A5E34888669A