SMC30: Pulse encoder
Figure 8-43
Selecting the pulse encoder
● To enter special encoder configurations, click the Enter data radio button followed by the
Encoder data button - and then enter the encoder data.
● If the encoder connected at the SMC10 or SMC30 is also used as actual value for the
closed-loop speed control, then under n-controller act. val. selection, select entry "[5]
DRIVE-CLiQ encoder".
● Run through the wizard until the end and load the expanded project into the drive.