8.4 Commissioning using the AOP30 Operator Panel
Acquiring the motor data
The motor data can be taken from the motor rating plate.
Figure 8-4
p2003
p50100[D]
p50101[D]
p50102[D]
p50103[D]
p50114[D]
When you have finished entering the motor data, select "Next" below the final parameter
value and activate with <F5> (OK).
Encoder selection
p50083[D]
Analog tachometer screen
p50741[D]
p2000
250
Example of a rating plate
Rated torque = (kW x 9555) / rated speed
Rated armature current
Rated armature voltage
Rated excitation current
Minimum excitation current (optional)
Thermal time constant for motor
See the section titled "Thermal overload protection for the DC motor (I
monitoring of the motor)"
Actual speed controller value selection
Tachometer voltage at maximum speed
Reference speed