8.4.1.2
Full drive commissioning
Entering power unit data
p51819[0]
p51819[1]
p51820
p51821[0]
p51821[1]
p51822
p51823
p51824
p51825
p51826[0]
p51826[1]
p51829
p51830
p51831
p51832
p51833
p51834
p51835[0]
p51835[1]
p51835[2]
Adjust the rated device currents
The rated armature DC current for the device must be adjusted by setting p50076[0] (in %)
or p50067 if:
Maximum armature current < 0.5 × rated armature DC current for the device
The rated field DC current for the device must be adapted by setting p50076[1] (in %) if:
Maximum field current < 0.5 × rated field DC current for the device
Adapt to the actual device supply voltage
p50078[0]
p50078[1]
SINAMICS DCM Control Module
Operating Instructions, 12/2018, A5E34888669A
Transformation ratio for armature voltage transformer
Transformation ratio for field voltage transformer
Rated armature supply voltage
Connection of line measurement cables
Connection of armature measurement cables
Rated armature DC current
Load voltage at rated armature current
Current transformer configuration
Type of power unit
Length of first pulse
Length of other pulses
Heat sink temperature threshold
Sensor for heat sink temperature
Fuse monitoring
Monitoring of unit fan
External fault
Source of fan relay output
Monitoring of unit fan's ON delay
Fault involving unit fan's ON delay
Alarm involving unit fan's ON delay
Rated value for armature supply voltage (in volts)
Rated value for field supply voltage (in volts)
8.4 Commissioning using the AOP30 Operator Panel
Commissioning
249