P5-xx Motion Setting Parameters

P5-00 ~
Reserved
P5-02
P5-03
PDEC Deceleration Time of Auto Protection
Operational
Interface:
Default: 0XEEFEEFF
Control
Mode:
Range: 0x00000000 ~ 0xFFFFFFFF
Data Size: 32-bit
Format: Hexadecimal
Settings: The parameter setting is divided into D, C, B, A, W, Z, Y, X
8-160
Panel / Software
ALL
Unit: -
(hexadecimal), including:
1. The deceleration time when activating the auto-protection function:
OVF (DO.0x11, poisiiton command / feedback overflows), CTO
(communication timeout AL020), SPL, SNL, PL, NL
2. Deceleration time of Stop Command: STP
Item
D
Function
STP
Range
0~ F
0 ~ F is used to indexing the deceleration time of P5-20 ~ P5-35.
For example: If X is set to A, then the deceleration time of PL is
Communication
C
B
CTO
PFQS
0~ F
0 ~ F
determined by P5-30.
Address: 0506H
Related Section: -
A
W
Z
OVF
SNL
SPL
0~ F
0~ F
0~ F
ASDA-A2
0507H
Y
X
NL
PL
0~ F 0~ F