ASDA-A2
2.5 Specification of Circuit Breaker and Fuse
220V Series
Caution: Please use the fuse and circuit breaker that are recognized by UL / CSA.
Servo Drive Model
Operation Mode
ASD-A2-0121-
ASD-A2-0221-
ASD-A2-0421-
ASD-A2-0721-
ASD-A2-1021-
ASD-A2-1521-
ASD-A2-2023-
ASD-A2-3023-
ASD-A2-4523-
ASD-A2-5523-
ASD-A2-7523-
ASD-A2-1B23-
ASD-A2-1F23-
Note: If the servo drive equips with earth leakage circuit breaker for avoiding electric leakage, please choose
the current sensitivity which is over 200 mA and can continue up to 0.1 seconds.
400V Series
Caution: Please use the fuse and circuit breaker that are recognized by UL / CSA.
Servo Drive Model
Operation Mode
ASD-A2-0443-
ASD-A2-0743-
ASD-A2-1043-
ASD-A2-1543-
ASD-A2-2043-
ASD-A2-3043-
ASD-A2-4543-
ASD-A2-5543-
ASD-A2-7543-
Note: If the servo drive equips with earth leakage circuit breaker for avoiding electric leakage, please
choose the current sensitivity which is over 200 mA and can continue up to 0.1 seconds.
2-4
Circuit Breaker
General
5A
5A
10A
10A
15A
20A
30A
30A
70A
75A
95A
-
-
Circuit Breaker
General
10A
10A
15A
20A
25A
30A
50A
60A
70A
Chapter 2 Installation
Fuse (Class T)
General
5A
5A
10A
20A
25A
40A
50A
70A
140A
150A
175A
-
-
Fuse (Class T)
General
10A
15A
20A
25A
30A
50A
80A
90A
120A