P1-Xx Basic Parameters - Delta ASD-A2-0121 Series User Manual

Ac servo drive for network communication applications
Hide thumbs Also See for ASD-A2-0121 Series:
Table of Contents

Advertisement

ASDA-A2

P1-xx Basic Parameters

P1-00▲
PTT
Operational
Interface:
Default: 0x0002
Control
Mode:
Range: 0x0000 ~ 0x1142
Data Size: 16-bit
Format: Hexadecimal
Settings:
The Type of External Pulse Input
Panel / Software
PT
Unit: -
 Pulse Type
0: AB phase pulse (4x)
1: Clockwise (CW) and Counterclockwise (CCW) pulse
2: Pulse + symbol
Other setting: reserved
 Filter Width
If the received frequency is much higher than the setting, it will be
regarded as the noise and filtered out.
Min. pulse width*
Setting
(Low-speed filter
Value
frequency)
0
600 ns (0.83 Mpps)
1
2.4 us (208 Kpps)
2
4.8 us (104 Kpps)
3
9.6 us (52 Kpps)
4
No filter function
Communication
note1
Setting
Value
0
1
2
3
4
Chapter 8 Parameters
Address: 0100H
0101H
Related Section:
6.2.1
Min. pulse width*
note1
(High-speed filter
frequency)
150 ns (3.33 Mpps)
600 ns (0.83 Mpps)
1.2 us (416 Kpps)
2.4 us (208 Kpps)
No filter function
8-37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents