Jog Mode - Delta ASD-A2-0121 Series User Manual

Ac servo drive for network communication applications
Hide thumbs Also See for ASD-A2-0121 Series:
Table of Contents

Advertisement

ASDA-A2

4.4.2 JOG Mode

When it is in Parameter Mode, select P4-05 and follow the setting method below for JOG operation
(The communication mode does not support using the panel to set the JOG mode).
(1) Press the SET key to display the speed value of JOG. The default value is 20 r/min.
(2) Press the UP or DOWN key to adjust the desired speed value of JOG. It is adjusted to
100 r/min in the example.
(3) Press the SET key to display JOG and enter JOG mode.
(4) When it is in JOG Mode, press the UP or DOWN key to enable the servo motor in forward or
reverse direction. The servo motor stops running as soon as the user stops pressing the key.
JOG operation is working only when it is Servo ON.
4-10
SET
SET
JOG Mode
P(CCW)
N(CW)
MODE
Exit
Chapter 4 Panel Display and Operation
Display JOG speed value.
Its default value is 20 r/min.
Press the UP/DOWN keys to adjust
JOG speed.
Adjust to 100 r/min.
Display JOG and enter JOG Mode.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents