Force Do Output - Delta ASD-A2-0121 Series User Manual

Ac servo drive for network communication applications
Hide thumbs Also See for ASD-A2-0121 Series:
Table of Contents

Advertisement

Chapter 4 Panel Display and Operation

4.4.3 Force DO Output

Enter the Digital Output Mode by the following settings. Set P2-08 to 406 and enable the function
of force DO mode. Then, set the force DO output by binary method via P4-06. When the setting
value is 2, DO2 will be forced to enable. When the setting value is 5, DO1 and DO3 will be forced
to enable. No data is retained in this mode. It returns to the normal DO mode when re-powering on
the drive or setting P2-08 to 400.
Note: P4-06 is displayed in hexadecimal format. Therefore, it will not show the fifth 0.
SET
SET
Force to enable
DO mode
SET
Force to enable DO1
Force to enable DO2
Force to enable DO3
Force to enable DO4
Force to enable DO5
Force to enable DO1, DO3
Force to enable DO1,
DO2, DO3
ASDA-A2
4-11

Hide quick links: