P5-Xx Motion Setting Parameters - Delta ASD-A2R-0221 Series User Manual

Asda-a2r series a high performance with diverse communication interfaces servo drive
Table of Contents

Advertisement

Chapter 8 ParametersASDA-A2R Series

P5-xx Motion Setting Parameters

P5-00
Reserved
P5-01
Reserved
P5-02
Reserved
P5-03
PDEC Deceleration Time of Auto Protection
Operational
Interface:
Default: 0XE0EFEEFF
Control
Mode:
Unit: -
Range: 0x00000000 ~ 0xF0FFFFFF
Data Size: 32bit
Format: HEX
Settings: The parameter setting is divided into D, C, B, A, W, Z, Y, X
P5-04
HMOV Homing Mode
Operational
Interface:
Default: 0
Control
Mode:
Unit: -
8-138
Panel / Software
ALL
(hexadecimal), including:
1. The deceleration time when activating the auto-protection
function: OVF, CTO (communication timeout AL020), SPL,
SNL, PL, NL
2. Deceleration time of Stop Command: STP
Item
D
Function STP
Reserved CTO
Range
0~ F
0 ~ F is used to indexing the deceleration time of P5-20~P5-35.
For example: If X is set to A, then the deceleration time of PL is
determined by P5-30.
Panel / Software
PR
Communication
C
B
A
OVF
0~ F 0~ F
Communication
Address: 0500H
0501H
Address: 0502H
0503H
Address: 0504H
0505H
Address: 0506H
0507H
Related Section: -
W
Z
Y
SNL
SPL
NL
0~ F
0~ F 0~ F 0~ F
Address: 0508H
0509H
Related Section: -
Revision December, 2014
X
PL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents