2.4 Setting Commands
p3 action
Description
Option
Switch to REMOTE
REM_
(REM) LP1
LP1
Switch to REMOTE
REM_
(REM) LP2
LP2
Switch to LOCAL
LCL_LP1
(LCL) LP1
Switch to LOCAL
LCL_LP2
(LCL) LP2
Auto-tuning START/
AT_LP1
STOP Switch (AT)
LP1
Auto-tuning START/
AT_LP2
STOP Switch (AT)
LP2
PV switching (SW)
SW
Alarm ACK (ACK)
ACK_LP1
LP1
Alarm ACK (ACK)
ACK_LP2
LP2
Bit-0 of SP Number
SPBit0_
LP1
LP1
Bit-1 of SP Number
SPBit1_
LP1
LP1
Bit-2 of SP Number
SPBit2_
LP1
LP1
Bit-3 of SP Number
SPBit3_
LP1
LP1
Bit-0 of SP Number
SPBit0_
LP2
LP2
2-76
p4 options
Off
ALM1_
ALM1_
Conditions
DI1 to
L1 to
L2 to
in which
DI8
ALM4_
ALM4_
p3 is valid
DO1 to
L1
L2
when p4 is
DO8
ALO1_
ALO1_
L1 to
L2 to
not Off
ALO4_
ALO4_
L1
L2
x
x
Valid when
the RSP
function is
on (see odd
loops)
Valid when
x
x
the RSP
function is
on (see even
loops)
Valid when
the control
mode is
single loop
(for cascade,
the RSP
function is
fixed to off)
x
x
Valid when
the RSP
function is
on (see odd
loops)
Valid when
x
x
the RSP
function is
on (see even
loops)
Valid when
the control
mode is
single loop
(for cascade,
the RSP
function is
fixed to off)
x
x
Always valid
Valid when
x
x
the control
mode is not
PV switching
x
x
Valid when
the control
mode is PV
switching
and the input
switching
action is
contact.
x
x
Always valid
Valid when
x
x
the control
mode is not
PV switching
x
x
Always valid
x
x
Always valid
x
x
Always valid
Always valid
x
x
x
x
Valid when
the control
mode is not
PV switching
p3 action
Description
Option
Bit-1 of SP Number
SPBit1_
LP2
LP2
Bit-2 of SP Number
SPBit2_
LP2
LP2
Bit-3 of SP Number
SPBit3_
LP2
LP2
Bit-0 of PID Number
PIDBit0_
LP1
LP1
Bit-1 of PID Number
PIDBit1_
LP1
LP1
Bit-2 of PID Number
PIDBit2_
LP1
LP1
Bit-3 of PID Number
PIDBit3_
LP1
LP1
Bit-0 of PID Number
PIDBit0_
LP2
LP2
Bit-1 of PID Number
PIDBit1_
LP2
LP2
p4 options
Off
ALM1_
ALM1_
Conditions
DI1 to
L1 to
L2 to
in which
DI8
ALM4_
ALM4_
p3 is valid
DO1 to
L1
L2
when p4 is
DO8
ALO1_
ALO1_
L1 to
L2 to
not Off
ALO4_
ALO4_
L1
L2
x
x
Valid when
the control
mode is not
PV switching
Valid when
x
x
the control
mode is not
PV switching
x
x
Valid when
the control
mode is not
PV switching
x
x
Valid when
the PID
selection
is external
selection
(see odd loop
settings)
Valid when
x
x
the PID
selection
is external
selection
(see odd loop
settings)
x
x
Valid when
the PID
selection
is external
selection
(see odd loop
settings)
Valid when
x
x
the PID
selection
is external
selection
(see odd loop
settings)
x
x
Valid when
the PID
selection
is external
selection
(see even
loop settings)
Valid when
the control
mode is not
PV switching
Valid when
x
x
the PID
selection
is external
selection
(see
even loop
settings).
Valid when
the control
mode is not
PV switching.
IM 04L51B01-17EN