2.4 Setting Commands
SMonitor
Monitor Screen Display Information [GX/
GP]
Sets the monitor screen display information.
Syntax
SMonitor,p1,p2
p1 Information type (see the table below)
p2 Status (see the table below)
Information Type
p1
Description
Digital
Digital value display
Scroll
Auto scroll
Message
Message display
Trend
All channel/group display Group, All
Grid
Auxiliary grid
Axis
Time axis on historical
trend
Value
Digital value display on
historical trend
Historical data type
Data
DigitalWave
Digital waveform display Off, On
Alarm
Alarm display
Alarm_Sort
Alarm sort item
Alarm sort order
Alarm_Order
Alarm_Time
Detailed alarm time
Message_Sort Message sort item
Message_Order Message sort order
Memory_Data
Memory data type
Overview display
Overview
Multi_No
Multi panel number
Custom_No
Customized display
screen number (/CG)
DigitalPos
Digital display position
DigitalLabel Display string display
Modbus_M
Modbus master status
display type (/MC)
Modbus client status
Modbus_C
display type (/MC)
Watt
WT communication
status display type (/E2)
Switch
Internal switch/DO status
display
SLMP_C
SLMP client status
display type (/E4)
ControlGroup Control group
ControlAlarm_
Control alarm sort item
Sort
Control alarm sort order Ascending,
ControlAlarm_
Order
ControlAlarm_
Control alarm summary
Time
millisecond display
Query
SMonitor[,p1]?
2-66
Example Set the trend display to all-channel display.
Description
Status
p2
Off, On
Multi Panel Division [GX/GP]
Off, On
Stream, List
Sets the multi panel multi panel pattern.
Syntax
Off, On
1, 2, 3, 4, 5,
6, 7, 8
4Value, Max,
Min
Disp, Event1
Watch, List
Time, Channel,
Level, Type
Ascending,
Descending
Off, On
Datatime,
WriteTime,
Message,
Group, User
Query
Example Set the panel of registration number 1 to
Ascending,
Descending
Disp, Event1,
Event2
Grouping, All
Description
1 to 20
1 to 30
Default, Top,
Bottom, Left,
Right
Off, On
Overview, List
Overview, List
Overview, List
All, 1, 2, 3,
4
Overview, List
Controller,
Faceplate
Time, Loop,
Level, Type
Descending
Off, On
SMonitor,Trend,All
Custom_No is an option (/CG).
Modbus_M and Modbus_C are an option (/MC).
Watt is an option (/E2).
When p1 = Switch, p2 = 3 or 4 is valid only for the
GX10/GP10.
SMultiPattern
SMultiPattern,p1,p2,p3
p1 Registration number (1 to 20)
p2 Multi panel pattern
Wide2
Tall2
Wide3
Tall3
Split4
Even5
Odd5
Even6
Odd6
p3 Multi panel name (up to 16 characters,
UTF-8)
SMultiPattern[,p1]?
"Split 2 Wide." Set the multi panel name to
"Monitor1."
SMultiPattern,1,Wide2,'Monitor1'
This command is only valid for the GX20/GP20.
This command can be used only when the multi batch
function (/BT) is disabled.
Split 2 Wide
Split 2 Tall
Split 3 Wide
Split 3 Tall
Split 4 Even
Split 5 Even
Split 5 Odd
Split 6 Even
Split 6 Odd
IM 04L51B01-17EN