YOKOGAWA GX10 User Manual page 93

Gx series; gp series; gm series; smartdac+ communication command
Hide thumbs Also See for GX10:
Table of Contents

Advertisement

SCtrlDIRegist
Contact Registration
Registers a contact
Syntax
SCtrlDIRegist,p1,p2,p3,p4
p1 Unit number
p2 Module number
p3 Action
A-M_LP1
A-M_LP2
R-L_LP1
R-L_LP2
S-R_LP1
S-R_LP2
CAS
AUTO_LP1
AUTO_LP2
MAN_LP1
MAN_LP2
REM_LP1
REM_LP2
LCL_LP1
LCL_LP2
AT_LP1
AT_LP2
SW
ACK_LP1
ACK_LP2
SPBit0_LP1
SPBit1_LP1
SPBit2_LP1
SPBit3_LP1
SPBit0_LP2
SPBit1_LP2
SPBit2_LP2
SPBit3_LP2
PIDBit0_LP1
PIDBit1_LP1
PIDBit2_LP1
PIDBit3_LP1
PIDBit0_LP2
PIDBit1_LP2
PIDBit2_LP2
PIDBit3_LP2
p4 Terminal number
Off
DI1to DI8
DO1 to DO8
ALM1_L1to
ALM4_L1
ALO1_L1to
ALO4_L1
ALM1_L2to
ALM4_L2
ALO1_L2 to
ALO4_L2
Query
SCtrlDIRegist[,p1,p2,p3]?
Example Set the AUTO/MAN Switch (A/M) LP1 of
module number 2 connected to the main unit
to DI1.
IM 04L51B01-17EN
AUTO/MAN Switch (A/M) LP1
AUTO/MAN Switch (A/M) LP2
REMOTE/LOCAL Switch (R/L)
LP1
REMOTE/LOCAL Switch (R/L)
LP2
STOP/RUN Switch (S/R) LP1
STOP/RUN Switch (S/R) LP2
Switch to Cascade (CAS)
Switch to AUTO (AUTO) LP1
Switch to AUTO (AUTO) LP2
Switch to MAN (MAN) LP1
Switch to MAN (MAN) LP2
Switch to REMOTE (REM) LP1
Switch to REMOTE (REM) LP2
Switch to LOCAL (LCL) LP1
Switch to LOCAL (LCL) LP2
Auto-tuning START/STOP Switch
(AT) LP1
Auto-tuning START/STOP Switch
(AT) LP2
PV switching (SW)
Alarm ACK (ACK) LP1
Alarm ACK (ACK) LP2
Bit-0 of SP Number LP1
Bit-1 of SP Number LP1
Bit-2 of SP Number LP1
Bit-3 of SP Number LP1
Bit-0 of SP Number LP2
Bit-1 of SP Number LP2
Bit-2 of SP Number LP2
Bit-3 of SP Number LP2
Bit-0 of PID Number LP1
Bit-1 of PID Number LP1
Bit-2 of PID Number LP1
Bit-3 of PID Number LP1
Bit-0 of PID Number LP2
Bit-1 of PID Number LP2
Bit-2 of PID Number LP2
Bit-3 of PID Number LP2
No registration
Contact input
Contact output
Alarm status loop 1
Alarm output loop 1
Alarm status loop 2
Alarm output loop 2
SCtrlDIRegist,0,2,A-M_LP1,DI1
Description
This command is valid when a PID Control Module is
installed.
ALM*_Lx(*=1 to 4, x=1 or 2) indicates the alarm
status. ALM*_OUT_Lx(*=1 to 4, x=1 or 2) indicates
the alarm output status including the relay action.
The valid range of p4 options varies depending on the
p3 (action) setting. For details, see the table below
("Validity of p3 settings and p4 terminal numbers").
Validity of p3 settings and p4 terminal numbers
p3 action
p4 options
Description
Option
Off
DI1 to
DI8
DO1 to
DO8
AUTO/MAN Switch
A-M_LP1
x
(A/M) LP1
AUTO/MAN Switch
A-M_LP2
x
(A/M) LP2
REMOTE/LOCAL
R-L_LP1
x
Switch (R/L) LP1
REMOTE/LOCAL
R-L_LP2
x
Switch (R/L) LP2
STOP/RUN Switch
S-R_LP1
x
(S/R) LP1
STOP/RUN Switch
S-R_LP2
x
(S/R) LP2
Switch to Cascade
CAS
x
(CAS)
Switch to AUTO
AUTO_
x
(AUTO) LP1
LP1
Switch to AUTO
AUTO_
x
(AUTO) LP2
LP2
Switch to MAN
MAN_
x
(MAN) LP1
LP1
Switch to MAN
MAN_
x
(MAN) LP2
LP2
2.4 Setting Commands
x: valid
ALM1_
ALM1_
Conditions
L1 to
L2 to
in which
ALM4_
ALM4_
p3 is valid
L1
L2
when p4 is
ALO1_
ALO1_
L1 to
L2 to
not Off
ALO4_
ALO4_
L1
L2
x
Valid when
the control
mode is not
cascade
Valid when
x
the control
mode is not
PV switching
x
Valid when
the RSP
function is
on (see odd
loops)
Valid when
x
the RSP
function is
on (see even
loops)
Valid when
the control
mode is
single loop
(for cascade,
the RSP
function is
fixed to off)
Always valid
x
x
Valid when
the control
mode is not
PV switching
x
Valid when
the control
mode is
cascade
x
Valid when
the control
mode is not
cascade
x
Valid when
the control
mode is not
PV switching
x
Valid when
the control
mode is not
cascade
Valid when
x
the control
mode is not
PV switching
2-75
1
2
App

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gm10Gx20Gp20Gp10

Table of Contents