YOKOGAWA GX10 User Manual page 178

Gx series; gp series; gm series; smartdac+ communication command
Hide thumbs Also See for GX10:
Table of Contents

Advertisement

2.10 ASCII Output Format
2-160
Output example when an expandable I/O or sub unit is connected
• The unit information area (e.g. U00) will contain the expansion module name. All seven
units are output regardless of whether expansion modules are available.
• The module information area (after Unit) will contain I/O module names. Only the units
that have modules installed will be output.
EA
U00*:GX20-1J
U01 :GX90EX-02-TP1
U02 :---------------- ---------------- ----------------
U03 :---------------- ---------------- ----------------
U04 :---------------- ---------------- ----------------
U05 :---------------- ---------------- ----------------
U06 :---------------- ---------------- ----------------
Unit:00
00:GX90XA-10-U2
01:GX90XA-10-U2
02:---------------- ---------------- ----------------
03:---------------- ---------------- ----------------
04:---------------- ---------------- ----------------
05:---------------- ---------------- ----------------
06:---------------- ---------------- ----------------
07:---------------- ---------------- ----------------
08:---------------- ---------------- ----------------
09:---------------- ---------------- ----------------
Unit:01
00:GX90XA-10-U2
01:---------------- ---------------- ----------------
02:---------------- ---------------- ----------------
03:---------------- ---------------- ----------------
04:---------------- ---------------- ----------------
05:---------------- ---------------- ----------------
06:---------------- ---------------- ----------------
07:---------------- ---------------- ----------------
08:---------------- ---------------- ----------------
09:---------------- ---------------- ----------------
EN
cccccccccccccccc
uuuuuuuuuuuuuuuu
defghijklmnopqrs
nn
f
GX20-1J
GX90EX-02-TP1
GX90XA-10-U2
----------------
GX90XA-10-U2
----------------
GX90XA-10-U2
----------------
Module models that are actually installed
--------------------
Displays the module model code.
Module models recognized by the GX
--------------------
Displays the module model code.
Module status
-
Normal
X
Error
d to s express the following items.
d
System data error
e
Calibration value error
f
Parameter error
g
Reserved (-)
FRAM error
h
Reserved (-)
i
Reserved (-)
j
Reserved (-)
k
l
A/D error
m
RJC error
n
Reserved (-)
o
Reserved (-)
p
Reserved (-)
q
Reserved (-)
r
Reserved (-)
s
Reserved (-)
Unit number
*
GX/GP or GM main unit
----------------
----------------
Module not installed (16 hyphens)
Module not installed (16 hyphens)
IM 04L51B01-17EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gm10Gx20Gp20Gp10

Table of Contents