Conditions p7
p6
Action
Value
Type
Rising,
Recording
Memory
Falling,
Edge
Math (math
Math
channel)
Display rate
RateChange
switch
[GX/GP]
Flag
Flag
Manual
ManualSample
sample
1
DO output
DO
Output to
SW
an internal
2
switch
Alarm ACK AlarmACK
Snapshot
Snapshot
[GX/GP]
Time
TimeAdjust
adjustment
Display data
SaveDisplay
save
Event data
SaveEvent
save
Event
Trigger
3
trigger
Message
Message
Display
GroupChange
group
change
[GX/GP]
Relative
TimerReset
timer reset
Settings
ConfigLoad
load
Settings
ConfigSave
save [GM]
Favorite
PlayList
screen
display [GX/
GP]
Pattern file
ProgPatLoad
5
load
Both
Recording
MemoryStartStop -
start/stop
Math start/
MathStartStop
stop
Display rate
RateChange1_2
switch 1/2
[GX/GP]
Flag On/Off FlagOn_Off
1
DO On/Off
DOOn_Off
Internal
SWOn_Off
switch on/
2
off
1
Can be output only to DO whose type is set to Manual.
2
Can be output only to SW whose type is set to Manual.
3
Valid when the advanced security function (/AS) is disabled.
4
For the setting range, see section 2.3.2, "Parameter Notation and
Range."
5
This is valid only for the program control function (/PG).
Query
SEventAct[,p1]?
Invalid parameters are returned as blanks in
queries.
Example Execute memory start on the rising edge of the
remote control input (channel 0101). Use event
action number 2.
SEventAct,2,On,DI,0101,,Rising,Mem
ory,,Start
Description
IM 04L51B01-17EN
p8
p9
p10
p11
Source
Action
Action
Action
Element
Detail
Detail 2
Detail 3
Number
1
-
Start,
-
ALL, batch
Stop
group
*4
number
-
Start,
-
-
Stop,
Reset
1, 2
Reset
-
ALL, batch
group
*4
number
1 to 20
-
-
-
-
-
-
-
Channel
Off, On -
-
number
Channel
Off, On -
-
number
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ALL, batch
group
*4
number
1
-
-
ALL, batch
group
*4
number
1, 2
-
-
-
1 to 100
All,
Display
Batch
Select
group
group
*4
*4
number
number
Display
-
-
Batch
group
group
*4
*4
number
number
1 to 12
-
-
-
1 to 10
-
-
-
1 to 10
-
-
-
1 to 20
-
-
-
1 to 10
-
-
-
-
-
ALL, batch
group
*4
number
-
-
-
-
-
-
-
1 to 20
-
-
-
Channel
-
-
-
number
Channel
-
-
-
number
There are limitations to event and action
combinations. For details, see section 1.14 in the
Model GX10/GX20/GP10/GP20 Paperless Recorder
User's Manual (IM 04L51B01-01EN) or section 2.15,
"Configuring the Event Action Function," in the Data
Acquisition System GM User's Manual (IM 04L55B01-
01EN).
Write only delimiters (commas) for irrelevant
parameters (invalid even if a value is specified).
Event type "DI" is the channel of the DI module that
has been set to remote module
You can specify p3 = Status and p6 = Both when
an item that can be specified as an action (flag, DO
channel, or internal switch) is valid.
Math channel and flag are an option (/MT).
Communication channels are an option (/MC).